The KMC series gages are designed to measure self-shrinkage and self-stress of cemented materials. They enable measurement of the self-shrinkage and high-fluidity concrete immediately after placing. They are also used effectively to check for cracks of cemented materials. Usually, a T-type thermocouple is installed near the gage, while the KMC series gages of H4 type do not require such the installation since they are equipped with a built-in thermocouple.
Specifications
- Materials Resistive element
-
CuNi alloy wire
- Materials Base
-
Silicone
- Operating temperature in combination with major adhesives after curing
-
Embedment: normal temperature to 70
°C
- Operating temperature in combination with major leadwire cables
-
Vinyl-coated flat 3-wire cable: Normal temperature to 70
°C
- Strain limit at room temp.
-
0.3
%
- Nennwiderstand
-
120
Ω
- Dimensions
-
80x
10
x
2
mm
- Stück pro Packung
-
1
Stück