WGA-680A – High-Speed Instrumentation Amplifier
4000 Hz, three-colour digital display
Order on request
These products are requested only from ZSE. Our employees will contact you as soon as possible with an offer.
Order on request
This product is ordered on request! An account at myZSE gives you the opportunity to order this product directly.
High-performance Instrumentation Amplifier with High-speed sampling.
The WGA-680A series is compact, low-cost instrumentation amplifiers enabling direct reading of physical quantities such as load through high-speed sampling of signals from a strain gage transducer.
Features:
High-performance processing(Sampling rate: 4000 times/s, ADC resolution: 24 bits)
Applicable Bridge Resistance 87.5 to 1000 Ohm
Bridge Excitation 10VDC, 2VDC, selectable
Smoothing Function: Filter and Moving average
Hold Function
Analog (D/A) Output: Voltage or current mode
Control Inputs for Zero, Hold and Reset
Control Outputs: 5 OC 30VDC for HH, HI, OK, LO, and LL
Substantial comparison functions (Limit high, high, OK, low, and limit low)
Various optional interfaces(CC-Link, RS-485/TEDS, RS-232C/TEDS, and BCD/TEDS)
Power Supply options: 100 to 240ACV 50/60Hz or 10 to 30 VDC
Specifications
Channels
1
Applicable sensors
Strain-gage transducers (4-wire)
Applicable Bridge Resistance
87.50 – 1000 ΩI
Bridge Excitation
2, 10 VDCI
Measuring Range
±3.2 mV/V (Input range including zero adjustment range)
Non linearity
Within ±(0.02% FS+ 1digit) % FS
Calibration
Actual load calibration, sensitivity registering calibration, and numeric value registering calibration
Power Supply
AC Models: 100 to 240 VAC DC Models: 10 to 30 VDC
Dimensions
96x 126 x 96 mmI
Weight
750 gI
Operating Temperature
-10 – 50 °C
Operating Humidity
20 – 80 % RHI
Your search returned no results.
WGA-680A-00
Instrumentation Amplifier with D/A - Output
Power Supply: 100 ... 240VAC.
Extra-High, High / Low, Extra-Low Limit Comparator.
Request
S
WGA-680A-01
Instrumentation Amplifier with D/A - Output
Power Supply: 100 ... 240VAC.
Extra-High, High / Low, Extra-Low Limit Comparator.
Output Option: BCD/TEDS
BCD Output
Output
Data: 20 bits (4-bit×5) , POL (Minus polarity), over, EOC (End of Conversion), holding section, detecting section Output format: Open collector (30 VDC, 20 mA max.)
Input
Points: 2 (Hold, Output prohibited) Format: Non-voltage contact signal or open collector signal (Capacity: 12 VDC, 5 mA)
TEDS
applicable-transducers
Should have the information according to IEEE template No. 33 (Cable length should be 30 m or less.)
Interfaces
Compatible with IEEE1451.4 Mixed Mode Transducer Interface Class 2
Request
S
WGA-680A-02
Instrumentation Amplifier with D/A - Output
Power Supply: 100 ... 240VAC.
Extra-High, High / Low, Extra-Low Limit Comparator.
Output Option: RS-232/TEDS
RS-232C
signal-system
RS-232C Full duplex system
communication
Synchronous
TEDS
applicable-transducers
Should have the information according to IEEE template No. 33 (Cable length should be 30 m or less.)
Interfaces
Compatible with IEEE1451.4 Mixed Mode Transducer Interface Class 2
Request
S
WGA-680A-03
Instrumentation Amplifier with D/A - Output
Power Supply: 100 ... 240VAC.
Extra-High, High / Low, Extra-Low Limit Comparator.
Output Option: RS-485/TEDS
CC-Link
signal-system
RS-485 half duplex system
TEDS
applicable-transducers
Should have the information according to IEEE template No. 33 (Cable length should be 30 m or less.)
Interfaces
Compatible with IEEE1451.4 Mixed Mode Transducer Interface Class 2
Request
S
WGA-680A-04
Instrumentation Amplifier with D/A - Output
Power Supply: 100 ... 240VAC.
Extra-High, High / Low, Extra-Low Limit Comparator.
Output Option: CC-Link
CC-Link
version
1.10
station-types
Remote device station
occupied-stations
1, 2, 4
slave-stations
1 to 64
Dedicated Connection Cable
CC-Link version 1.10 compliant cables I
Request
S
WGA-680A-10
Instrumentation Amplifier with D/A - Output
Power Supply: 10 to 30VDC, max. 10W
Extra-High, High / Low, Extra-Low Limit Comparator.
Request
S
WGA-680A-11
Instrumentation Amplifier with D/A - Output
Power Supply: 10 to 30VDC, max. 10W
Extra-High, High / Low, Extra-Low Limit Comparator.
Output Option: BCD/TEDS
BCD Output
Output
Data: 20 bits (4-bit×5) , POL (Minus polarity), over, EOC (End of Conversion), holding section, detecting section Output format: Open collector (30 VDC, 20 mA max.)
Input
Points: 2 (Hold, Output prohibited) Format: Non-voltage contact signal or open collector signal (Capacity: 12 VDC, 5 mA)
TEDS
applicable-transducers
Should have the information according to IEEE template No. 33 (Cable length should be 30 m or less.)
Interfaces
Compatible with IEEE1451.4 Mixed Mode Transducer Interface Class 2
Request
S
WGA-680A-12
Instrumentation Amplifier with D/A - Output
Power Supply: 10 to 30VDC, max. 10W
Extra-High, High / Low, Extra-Low Limit Comparator.
Output Option: RS-232/TEDS
RS-232C
signal-system
RS-232C Full duplex system
communication
Synchronous
TEDS
applicable-transducers
Should have the information according to IEEE template No. 33 (Cable length should be 30 m or less.)
Interfaces
Compatible with IEEE1451.4 Mixed Mode Transducer Interface Class 2
Request
S
WGA-680A-13
Instrumentation Amplifier with D/A - Output
Power Supply: 10 to 30VDC, max. 10W
Extra-High, High / Low, Extra-Low Limit Comparator.
Output Option: RS-485/TEDS
CC-Link
signal-system
RS-485 half duplex system
TEDS
applicable-transducers
Should have the information according to IEEE template No. 33 (Cable length should be 30 m or less.)
Interfaces
Compatible with IEEE1451.4 Mixed Mode Transducer Interface Class 2
Request
S
WGA-680A-14
Instrumentation Amplifier with D/A - Output
Power Supply: 10 to 30VDC, max. 10W
Extra-High, High / Low, Extra-Low Limit Comparator.
Output Option: CC-Link
CC-Link
version
1.10
station-types
Remote device station
occupied-stations
1, 2, 4
slave-stations
1 to 64
Dedicated Connection Cable
CC-Link version 1.10 compliant cables I
Request
S
D
SJB – Junction Box
Cable extension for load cell and Models integration of multiple load cell outputs to a single cable
Request
S
SJB – Junction Box
Cable extension for load cell and Models integration of multiple load cell outputs to a single cable
A junction box is used when connecting a load cell and amplifier using an extension cable, or when connecting cables of multiple load cells, weighing a tank or hopper, to an amplifier using a single cable.
The SJB-C/D are designed for general purposes, for use under non hazardous and explosive environments.
Inputs
For one Load-Cell
For four Load-Cells
Cable Diameter
10 to 11 mm (15C, 4-conductor (0.5 mm²) shielded cable)
7 to 8 mm (10B, 4-conductor (0.3 mm²) shielded cable)
S
D
JBS – Junction Box
Cable extension for load cell and Models integration of multiple load cell outputs to a single cable
Request
S
JBS – Junction Box
Cable extension for load cell and Models integration of multiple load cell outputs to a single cable
A junction box is used when connecting a load cell and amplifier using an extension cable, or when connecting cables of multiple load cells, weighing a tank or hopper, to an amplifier using a single cable.
The JBS-C is designed for use under hazardous and explosive environments.
Cable Diameter: 10 to 11 mm (Please specify the cable diameter)
Inputs
For one Load-Cell
For four Load-Cells
S
Kyowa Electronic Instruments
KYOWA ELECTRONIC INSTRUMENTS CO, LTD. is a Japanese company that has been covering all core elements of industrial strain measurement technology since 1951.