VAQ-700A – Servo Amplifier for ASQ-Series Tranducers
Order on request
These products are requested only from ZSE. Our employees will contact you as soon as possible with an offer.
Order on request
This product is ordered on request!
An account at myZSE gives you the opportunity to order this product directly.
The VAQ-700A can simultaneously measure acceleration and velocity by 1-time integration, and displacement by 2-time integration. A portable housing (YB-506A) is optionally available to accommodate multiple instruments.
Features
- Simultaneous measurement of acceleration and displacement velocity.
- Easy-to-read LED indicator
- Multi-channel configuration with portable housings.
Specifications
- Channels
-
1
- Measuring Modes
-
Simultaneous measurement of acceleration, velocity and displacement.
- Output Voltage
-
±10
VI
- Operating Temperature
-
-10 –
50
°C
- Power Supply
-
100 VAC or 12 VDC
- Dimensions
-
262.5x
49
x
128.5
mm
- Weight
-
1.4
kg
Your search returned no results.
VAQ-700A
Servo Amplifier
When using ASQ-D-1
Measuring Acceleration
- Measuring Range
-
±9.807
m/s2I
- Range Select
-
0.01, 0.1, 1 G, OFF
- Calibration
-
Linked with selected range × 0.51
- Accuracy
-
±0.5
% FS
- Frequency Response
-
DC to 300 Hz (±5 %) in DC acceleration mode
0.1 to 300 Hz (±5 %) in AC acceleration mode
Measuring Velocity
- Measuring Range
-
±100
cm/s
- Range Select
-
1, 10, 100 cm/s, OFF
- Calibration
-
Linked with selected range × 0.5
- Accuracy
-
±1
% FS
- Frequency Response
-
0.1 –
100
HzI
Measuring Displacement
- Range Select
-
1, 10, 100 mm, OFF
- Calibration
-
Linked with selected range × 0.5
- Accuracy
-
±1
% FS
- Frequency Response
-
0.1 –
60
HzI
When using ASQ-D-2
Measuring Acceleration
- Measuring Range
-
±19.61
m/s2I
- Range Select
-
0.02, 0.2, 2 G, OFF
- Calibration
-
Linked with selected range x 0.51
- Accuracy
-
±0.5
% FS
- Frequency Response
-
DC to 300 Hz (±5 %) in DC acceleration mode
0.1 to 300 Hz (±5 %) in AC acceleration mode
Measuring Velocity
- Measuring Range
-
±200
cm/s
- Range Select
-
2, 20, 200 cm/s, OFF
- Calibration
-
Linked with selected range x 0.5
- Accuracy
-
±1
% FS
- Frequency Response
-
0.1 –
100
HzI
Measuring Displacement
- Measuring Range
-
±200
mm
- Range Select
-
2, 20, 200 mm, OFF
- Calibration
-
Linked with selected range x 0.5
- Accuracy
-
±1
% FS
- Frequency Response
-
0.1 –
60
HzI
When using ASQ-D-5
Measuring Acceleration
- Measuring Range
-
±49.03
m/s2I
- Range Select
-
0.05, 0.5, 5 G, OFF
- Calibration
-
Linked with selected range x 0.51
- Accuracy
-
±0.5
% FS
- Frequency Response
-
DC to 300 Hz (±5 %) in DC acceleration mode
0.1 to 300 Hz (±5 %) in AC acceleration mode
Measuring Displacement
- Measuring Range
-
±500
cm/s
- Range Select
-
5, 50, 500 cm/s, OFF
- Calibration
-
Linked with selected range x 0.5
- Accuracy
-
±1
% FSI
- Frequency Response
-
0.1 –
100
HzI
Measuring Velocity
- Measuring Range
-
±500
mm
- Range Select
-
5, 50, 500 mm, OFF
- Calibration
-
Linked with selected range x 0.5
- Accuracy
-
±1
% FS
- Frequency Response
-
0.1 –
60
HzI
Request
S
D
P-69 DC-Power-Cable
20-pin connector to 2 lateral open-shape terminals
Request
S
P-69 DC-Power-Cable
20-pin connector to 2 lateral open-shape terminals
For: CDV-900A(-DC), CDA-900A(-DC), DA-710A, VAQ-700A, DPM-911B, 912B, 913C,951A, 952A
Length: Approx. 2.0 m
S
D
YC-3A
Portable Housing Case for DPM-900 Series, CDV-900A, CDA-900A, VAQ-700A, DA-710A
[...]
Request
S
YC-3A
Portable Housing Case for DPM-900 Series, CDV-900A, CDA-900A, VAQ-700A, DA-710A
- Model
-
YC-3A
YC-3A-AC/DC
- Models
-
DPM-900 Series, CDV-900A, CDA-900A, VAQ-700A, DA-710A
- Number of housing units
-
3
- Power Supply
-
100 VAC (YC-3A)
100 VAC or 12 VDC (YC-3A-AC/DC)
- Standard Accessories
-
AC power cable P-17 (With 2-pin conversion plug CM-39)
3P-2P conversion plug
Instruction manual
- Optional accessories
-
Dummy panel for 1 channel YB-DUMMY
Handle for YC-A YC-HANDLE
S
D
YC-4A
Portable Housing Case for DPM-900 Series, CDV-900A, CDA-900A, VAQ-700A, DA-710A
[...]
Request
S
YC-4A
Portable Housing Case for DPM-900 Series, CDV-900A, CDA-900A, VAQ-700A, DA-710A
- Model
-
YC-4A
YC-4A-AC/DC
- Models
-
DPM-900 Series, CDV-900A, CDA-900A, VAQ-700A, DA-710A
- Number of housing units
-
4
- Power Supply
-
100 VAC (YC-4A)
100 VAC or 12 VDC (YC-4A-AC/DC)
- Standard Accessories
-
AC power cable P-17 (With 2-pin conversion plug CM-39)
3P-2P conversion plug
Instruction manual
- Optional accessories
-
Dummy panel for 1 channel YB-DUMMY
Handle for YC-A YC-HANDLE
S
D
YC-6A
Portable case to accommodate six units of VAQ-700A.Also available for 3, 4 or 8 units [...]
Request
S
YC-6A
Portable case to accommodate six units of VAQ-700A.
Also available for 3, 4 or 8 units.
- Model
-
YC-6A
YC-6A-AC/DC
- Models
-
DPM-900 Series, CDV-900A, CDA-900A, VAQ-700A, DA-710A
- Number of housing units
-
6
- Power Supply
-
100 VAC (YC-6A)
100 VAC or 12 VDC (YC-6A-AC/DC)
- Standard Accessories
-
AC power cable P-17 (With 2-pin conversion plug CM-39)
3P-2P conversion plug
Instruction manual
- Optional accessories
-
Dummy panel for 1 channel YB-DUMMY
Handle for YC-A YC-HANDLE
S
D
YC-8A
Portable Housing Case for DPM-900 Series, CDV-900A, CDA-900A, VAQ-700A, DA-710A
[...]
Request
S
YC-8A
Portable Housing Case for DPM-900 Series, CDV-900A, CDA-900A, VAQ-700A, DA-710A
- Model
-
YC-8A
YC-8A-AC/DC
- Models
-
DPM-900 Series, CDV-900A, CDA-900A, VAQ-700A, DA-710A
- Number of housing units
-
8
- Power Supply
-
100 VAC (YC-8A)
100 VAC or 12 VDC (YC-8A-AC/DC)
- Standard Accessories
-
AC power cable P-17 (With 2-pin conversion plug CM-39)
3P-2P conversion plug
Instruction manual
- Optional accessories
-
JIS rack mounting bracket YC-JIS
DIN rack mounting bracket YC-DIN
Dummy panel for 1 channel YB-DUMMY
Handle for YC-A YC-HANDLE
S
D
FA-1B
Amplifier Stand for DPM-900 Series, DA-710A, CDV-900A, CDA-900A, VAQ-700A
[...]
Request
S
FA-1B
Amplifier Stand for DPM-900 Series, DA-710A, CDV-900A, CDA-900A, VAQ-700A
S