LUR-B-SA1 – Jack Load Cell
(±10 kN – ±2 MN)
Order on request
These products are requested only from ZSE. Our employees will contact you as soon as possible with an offer.
Order on request
This product is ordered on request!
An account at myZSE gives you the opportunity to order this product directly.
LUR-B-SA1 series load cells are designed to measure loads applied to jacks when lifting up or moving a large machinery or structure in civil engineering and construction fields. These load cells enable the operators to prevent overloads, unbalanced loads, or movement of the center of gravity.
- Special design for jacks
- Moderate price
- Variety of capacity range
Specifications
Performance
- Rated Output
-
1 +/- 1% mV/V
Environmental Characteristics
- Safe Temperature Range
-
-10 – 60 °C
- Compensated Temperature Range
-
0 – 60 °C
- Temperature Effect on Zero
-
+/-0.01 % RO/ºC
- Temperature Effect on Output
-
+/-0.01 %/°C
Electrical Characteristics
- Safe Excitation Voltage
- 15 VI
- Recommended Excitation Voltage
-
1 – 12 VI
- Input Resistance
-
350 Ω +/-2%
- Output Resistance
-
350 Ω +/-2%
- Cable
-
Cable
Wires: 4 (0.3 mm2)
Isolation: Chloroprene
Diameter: 7.6 mm
Length: 10 m
Connector
Type: 1108-12A-10-7M (Sensor)
Type: PRC03-12A10-7M (Measuring instrument)
Mechanical Properties
- Safe Overloads
- 200 %
Your search returned no results.
LUR-B-10KNSA1
- Rated Capacity
-
10 kNI
- Nonlinearity
-
±0.2 % RO
- Hysteresis
-
±0.1 % RO
- Weight
-
1.40 kgI
Request
S
LUR-B-20KNSA1
- Rated Capacity
-
20 kNI
- Nonlinearity
-
±0.2 % RO
- Hysteresis
-
±0.1 % RO
- Weight
-
2.10 kgI
Request
S
LUR-B-30KNSA1
- Rated Capacity
-
30 kNI
- Nonlinearity
-
±0.2 % RO
- Hysteresis
-
±0.1 % RO
- Weight
-
2.20 kgI
Request
S
LUR-B-50KNSA1
- Rated Capacity
-
50 kNI
- Nonlinearity
-
±0.2 % RO
- Hysteresis
-
±0.2 % RO
- Weight
-
2.20 kgI
Request
S
LUR-B-100KNSA1
- Rated Capacity
-
100 kNI
- Nonlinearity
-
±0.2 % RO
- Hysteresis
-
±0.1 % RO
- Weight
-
2.50 kgI
Request
S
LUR-B-200KNSA1
- Rated Capacity
-
200 kNI
- Nonlinearity
-
±0.2 % RO
- Hysteresis
-
±0.1 % RO
- Weight
-
5.20 kgI
Request
S
LUR-B-300KNSA1
- Rated Capacity
-
300 kNI
- Nonlinearity
-
±0.5 % RO
- Hysteresis
-
±0.5 % RO
- Weight
-
8 kgI
Request
S
LUR-B-500KNSA1
- Rated Output
-
1 mV/V (2000 µm/m) oder höher % RO
- Hysteresis
-
±1 % RO °C
Request
S
LUR-B-1MNSA1
- Rated Capacity
-
1000 kNI
- Nonlinearity
-
±0.5 % RO
- Hysteresis
-
±0.5 % RO
- Weight
-
55 kgI
Request
S
LUR-B-1.5MNSA1
- Rated Capacity
-
1500 kNI
- Nonlinearity
-
±0.5 % RO
- Hysteresis
-
±0.5 % RO
- Weight
-
85 kgI
Request
S
LUR-B-2MNSA1
- Rated Capacity
-
2000 kNI
- Nonlinearity
-
±0.5 % RO
- Hysteresis
-
±0.5 % RO
- Weight
-
100 kgI
Request
S
D
S32-7
7 Pin Tajimi female connector
Request
S
S32-7
7 Pin Tajimi female connector
Suitable for many Kyowa sensors.
PRC03-32A10-7F10.5
Standard: NDIS4102 (7 pins)
S