PHL-A-B
Integrated Cable type
Order on request
These products are requested only from ZSE. Our employees will contact you as soon as possible with an offer.
Order on request
This product is ordered on request!
An account at myZSE gives you the opportunity to order this product directly.
PHL-A series pressure transducers are compact, lightweight, stable in performance and suitable for pressure measurement in limited space under high/low-temperature environments. Besides excellent response and dynamic characteristics ensured by the semi-flush diaphragm, the PHL-A series can suitably measure pressures of highly viscous heated fluids (e.g. melt resin), high-temperature gases and LPG/LNG tanks. (Patented)
Connector-equipped PHL-A-A is also available
Features
- Compact and lightweight
- High stability
- High frequency response
- TEDS-installed versions can be manufactured
Specifications
Performance
- Repeatability
-
0.2
% RO
Environmental Characteristics
- Safe Temperature Range
-
-196 –
210
°CI
- Compensated Temperature Range
-
-196 –
200
°CI
- Temperature Effect on Output
-
±0.03
%/°C
Electrical Characteristics
- Safe Excitation Voltage
-
6
VI
- Recommended Excitation Voltage
-
1 –
3
VI
- Input Resistance
-
350 Ω ±2 %
- Output Resistance
-
350 Ω ±2 %
- Cable
-
4-conductor (0.08 mm2) fluoroplastic shielded cable, 3.1 mm diameter by 30 cm long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is not connected to the case.)
Mechanical Properties
- Safe Overloads
-
150
%
- material
-
Liquid-contacting part: SUS 630
- Weight
-
20
gI
- Degree of protection
-
IP64 (IEC 60529)
- Mounting Screw
-
G1/8, male
- RoHS-Directive
-
Directive 2011/65/EU (RoHS)
- Standard Accessories
-
Gasket (Mild copper) (SS-105 O-ring is also usable.)
Your search returned no results.
PHL-A-1MP-B
Small-Sized High/low Temperature Pressure Transducer
Rated Capacity: 1 MPa
Natural Frequency (Approx.): 48 kHz
- Rated Capacity
-
1
MPa
- Nonlinearity
-
±0.5
% RO
- Hysteresis
-
±0.5
% RO
- Rated Output
-
2
mV/VI
- Temperature Effect on Zero
-
±0.05
% RO/ºC
- Natural Frequency
-
48
kHz
Request
S
PHL-A-2MP-B
Small-Sized High/low Temperature Pressure Transducer
Rated Capacity: 2 MPa
Natural Frequency (Approx.): 74 kHz
- Rated Capacity
-
2
MPa
- Nonlinearity
-
±0.5
% RO
- Hysteresis
-
±0.5
% RO
- Rated Output
-
2
mV/VI
- Temperature Effect on Zero
-
±0.05
% RO/ºC
- Natural Frequency
-
74
kHz
Request
S
PHL-A-3MP-B
Small-Sized High/low Temperature Pressure Transducer
Rated Capacity: 3 MPa
Natural Frequency (Approx.): 94 kHz
- Rated Capacity
-
3
MPa
- Nonlinearity
-
±0.3
% RO
- Hysteresis
-
±0.2
% RO
- Rated Output
-
2
mV/VI
- Temperature Effect on Zero
-
±0.05
% RO/ºC
- Natural Frequency
-
94
kHz
Request
S
PHL-A-5MP-B
Small-Sized High/low Temperature Pressure Transducer
Rated Capacity: 5 MPa
Natural Frequency (Approx.): 122 kHz
- Rated Capacity
-
5
MPa
- Nonlinearity
-
±0.3
% RO
- Hysteresis
-
±0.2
% RO
- Rated Output
-
2
mV/VI
- Temperature Effect on Zero
-
±0.03
% RO/ºC
- Natural Frequency
-
122
kHz
Request
S
PHL-A-10MP-B
Small-Sized High/low Temperature Pressure Transducer
Rated Capacity: 10 MPa
Natural Frequency (Approx.): 149 kHz
- Rated Capacity
-
10
MPa
- Nonlinearity
-
±0.3
% RO
- Hysteresis
-
±0.2
% RO
- Rated Output
-
2
mV/VI
- Temperature Effect on Zero
-
±0.03
% RO/ºC
- Natural Frequency
-
149
kHz
Request
S
PHL-A-20MP-B
Small-Sized High/low Temperature Pressure Transducer
Rated Capacity: 20 MPa
Natural Frequency (Approx.): 210kHz
- Rated Capacity
-
20
MPa
- Nonlinearity
-
±0.3
% RO
- Hysteresis
-
±0.2
% RO
- Rated Output
-
2
mV/VI
- Temperature Effect on Zero
-
±0.03
% RO/ºC
- Natural Frequency
-
210
kHz
Request
S
PHL-A-30MP-B
Small-Sized High/low Temperature Pressure Transducer
Rated Capacity: 30 MPa
Natural Frequency (Approx.): 250 kHz
- Rated Capacity
-
30
MPa
- Nonlinearity
-
±0.3
% RO
- Hysteresis
-
±0.2
% RO
- Rated Output
-
2
mV/VI
- Temperature Effect on Zero
-
±0.03
% RO/ºC
- Natural Frequency
-
250
kHz
Request
S
PHL-A-50MP-B
Small-Sized High/low Temperature Pressure Transducer
Rated Capacity: 50 MPa
Natural Frequency (Approx.): 294 kHz
- Rated Capacity
-
50
MPa
- Nonlinearity
-
±0.3
% RO
- Hysteresis
-
±0.2
% RO
- Rated Output
-
2
mV/VI
- Temperature Effect on Zero
-
±0.03
% RO/ºC
- Natural Frequency
-
294
kHz
Request
S