The new panel mount Instrumentation Amplifier WGA-910A by KYOWA features a 3.5" color LCD graphic display for wave forms and digital readings. It measures strain-gages and strain gage based transducers 4000 times per second with an resolution of 24 bits. The measured data is scaled and presented on the touch-panel-display. A selectable filter smoothes the curve if needed. The data is available on an analog monitor output, a serial interface or can be saved on a SD-Card for further analysis. Programmable alarms can detect abnormal conditions and switch digital output lines.
Features:
The measurement waveform can be displayed.
Touch-sensitive 3.5-inch TFT LCD ensures easy operation and monitoring.
The measurement waveform can be recorded (optional SD card is necessary).
Characters are large and easy to see.
TEDS compatibility for TEDS-based automatic calibration.
5 Comparator Settings: extra high (HH), high (HI), OK, low (LO), extra low (LL).
Comparison value, hysteresis band, comparator output logic and using comparator can be set.
Interfaces : Compatible with IEEE1451.4 Mixed Mode Transducer Interface Class 2 Applicable Transducers : Should have the information according to IEEE template No. 33. Cable length should be 30 m or less
Measuring Range
±3.2 mV/V (Input range includes zero adjustment range)
Bridge Excitation
2, 10 VDCI
Non linearity
Within ±(0.02 %FS+1 digit) % FS
Power Supply
100 – 240 VI
Operating Temperature
-10 – 40 °C
Operating Humidity
20 – 80 % RHI
Dimensions
100x 135 x 96 mmI
Weight
950 g
Standard Accessories
CD-ROM including instruction manual and software for SD card
BCD data : 20 bits(4 bit ×5 digit) Binary data : 18 bits (offset binary) Minus code : 1 bit Over : 1 bit End Of Conversion(EOC) : 1 bit Output format : Open-collector Capacity : 30 VDC, 20 mA (load resistance)
Input
Number of point : 2 Detail : Data hold input Negative logic(Hold at “L”) Output prohibit input Negative logic(Prohibition at “L”) Input signal type : Open collector or Non-voltage contact signal Voltage 12 VDC and current 5 mA can be applied
setting-content
Transmission speed : Approx. 16, 32, 64, 125, 250, 500, 1000 times/sec. Polarity logic, EOC logic, Data logic : Negative, Positive Data type : BCD, Binary Changeable BCD classification : Hold Value1, Hold Value2, Measured Value
BCD data : 20 bits(4 bit ×5 digit) Binary data : 18 bits (offset binary) Minus code : 1 bit Over : 1 bit End Of Conversion(EOC) : 1 bit Output format : Open-collector Capacity : 30 VDC, 20mA (load resistance)
Input
Number of point : 2 Detail : Data hold input Negative logic(Hold at “L”) Output prohibit input Negative logic(Prohibition at “L”) Input signal type : Open collector or Non-voltage contact signal Voltage 12 VDC and current 5 mA can be applied
setting-content
Transmission speed : Approx. 16, 32, 64, 125, 250, 500, 1000 times/sec. Polarity logic, EOC logic, Data logic : Negative, Positive Data type : BCD, Binary Changeable BCD classification : Hold Value1, Hold Value2, Measured Value
D/A Output
Output Voltage
+/-10 VI
Current Output
4 – 20 mAI
Non linearity
Within ±0.1 %FS % FS
setting-content
D/A display : Zero disp. (Displayed value when the voltage 0 V is outputted) Full disp. (Displayed value when the voltage 10 V is outputted) D/A classification : Hold Value1, Hold Value2, Measured Value
Cable extension for load cell and Models integration of multiple load cell outputs to a single cable
A junction box is used when connecting a load cell and amplifier using an extension cable, or when connecting cables of multiple load cells, weighing a tank or hopper, to an amplifier using a single cable.
The SJB-C/D are designed for general purposes, for use under non hazardous and explosive environments.
Cable extension for load cell and Models integration of multiple load cell outputs to a single cable
A junction box is used when connecting a load cell and amplifier using an extension cable, or when connecting cables of multiple load cells, weighing a tank or hopper, to an amplifier using a single cable.
The JBS-C is designed for use under hazardous and explosive environments.
Cable Diameter: 10 to 11 mm (Please specify the cable diameter)