Analogeingang
See spec of respective conditioner cards.
Digital I/O
I/O points: Max .8
I/O Settings: Sets every bit to digital input, digital output, or remote-control input with the same common.
*Remote-control input: Measuring start, stop, balance conducting, etc.
Input modes: Isolated, TTL level input
Input voltage: Max. 5 VDC
Isolation modes: Digital isolation
Output modes:Isolated open-collector output (With 10 kΩ built-in pull-up resistors)
Output voltage: 5 VDC
Output current: Max. 25 mA (per point)
Sprachmemoeingabe
1 channel (To be recorded together with measuring data.) An optional remote control unit RCU-42 is required.
Abtastmodus
1-2-5 series
1 Hz to 200 kHz for up to 32-channel data acquisition
1 Hz to 100 kHz for up to 64-channel data acquisition
1 Hz to 50 kHz for up to 80-channel data acquisition
1 Hz to 10 kHz for real-time synchronous data processing
2n series
2 to 131.072 Hz for up to 32-channel data acquisition
2 to 65.5536 Hz for up to 64-channel data acquisition
2 to 32.768 Hz for up to 80-channel data acquisition
2 to 8.192 Hz for real-time synchronous data processing
*The condition is using a 16-bit A/D converter.
*As for a 24-bit A/D converter, the channels above will be half of each channel.
Bildschirm
I
Tastenbedienung
Keys (REC, STOP, BAL, and OPT) are operated by touchscreen, keys on EDX, external keyboard, or mouse
Ausgangskontrollanschluss
CONT.IN, CONT.OUT
(For remote control unit, or synchronous operation)
Externe I/O Stecker
External triggers: TRG IN, TRG OUT
External clock: CLK IN, CLK OUT
(Output at any frequency division ratio)
Externe Schnittstellen
USB type keyboard, USB type mouse
VGA connector for monitor
USB I/F: 3 USB 2.0 in front, 2 USB 3.0 in rear
LAN I/F: 100/1000BASE-T
Netzteil
100 to 240 VAC and 10 to 30 DC, dual supply
Built-in batteries against momentary power failure
Betriebstemperatur
0 –
40
°C
Betriebsluftfeuchtigkeit
20 –
80
% RHI
Lagerungstemperatur
-20 –
60
°C
Vibrationsbeständigkeit
EDX-5000A-64-HE, EDX-5000A-64-SE
49.0 m/s2 (5 G), 5 to 55 Hz (When not operating)
29.4 m/s2 (3 G), 5 to 55 Hz (When operating)
EDX-5000A-64-HE:
9.8 m/s2 (1 G), 10 to 200 Hz (When operating)
EDX-5000A-64-SE:
19.6 m/s2 (2 G), 10 to 200 Hz (When operating)
Schlagfest
196.1
m/s2I
Optionale Funktionen
CAN data acquisition (Input channels: Max 512)
GPS data acquisition (Tracing data acquisition, time synchronous function)
Onlinekontrolle
Controlled by DCS-100A