Nennausgangssignal (RO)
ca. 1 mV/V (±2000 µm/m)
Linearitätsabweichung
0,5 % RO
Linearitätsabweichung
0,5 % RO
Temperaturkompensierter Bereich
-20 –
50
°C
Temperaturkompensierter Bereich
-20 –
50
°C
Überlastbarkeit
120 %
Überlastbarkeit
Strain (Gage, transducer), voltage, thermocouples, pulse (F/V), piezoelectric acceleration (Built-in amplifier), CAN signals
Sprachmemoeingabe
1 channel (Input voice memo data is recorded together with the measurement data.)
Use remote control unit RCU-42A. (Optional accessory)
Use the Data Analysis Software DAS-200A (optional accessory) to play back recorded voice memos.
Akquisekanal
Normalmodus
Max. 32 channels, 320 k/I (I is the integer part of the set sampling frequency.)
Dualbetrieb
Max. 64 channels, 320 k/I (I is the integer part of the set sampling frequency.)
Digitalfilter
Butterworth filter (IIR)
Type of filter : LPF, HPF
Order of a Filter : 1 to 8
Amplitude ratio at cutoff point : -3 dB
Attenuation : -6 x N dB/oct. (N is filtering times )
Simultaneously use with built-in LPF possible.
Application on CAN data not possible.
Messziele
Strain (Gage, transducer), voltage, thermocouples, pulse (F/V), piezoelectric acceleration (Built-in amplifier), CAN signals
Messziele
Strain (Gage, transducer), voltage, thermocouples, pulse (F/V), piezoelectric acceleration (Built-in amplifier), CAN signals
Speicher Bedingungen
Recording of conditioner configuration conditions and measurement conditions within the EDX built- in nonvolatile memory.
Immediate start of data collection using the previously configured measurement conditions after power-on is possible.
Messmodus
Manual measurement/trigger measurement/interval measurement
Manual Measurement : Data recording is manually started or stopped when data is recorded to a preset number of measured data.
Manual mode allows recording of voice memo during data recording.
Trigger Measurement : Data recording is automatically started when the preset trigger condition is satisfied.
*No CAN data of CAN-41A is used as the trigger condition.
Interval Measurement : Automatically recording functions based upon previously-set interval conditions
Combination with measured mode when in dual sampling
Combination with Measured Mode when in Dual Sampling : (High-speed sampling channel - Low-speed sampling channel)
Manual setting - Manual setting
Trigger setting - Manual setting
Trigger setting - Interval setting
Interval setting - Interval setting
Manueller Start/Stop der Datenaufzeichnung
PC, operation switch (panel screen),
or using dedicated remote control
Gleichgewichtseinstellung
Strain input channel balance adjustment is performed using PC, operation switch (panel screen), or dedicated remote control
TEDS
Only when using online control from a PC
Supported conditioner cards: CDV-40B (-F), DPM-42B (-F), DPM-42B-I (-F), CCA-40A (-F), CDV-44AS, CDA-44AS, CDA-45AS, CVM-41A
Es ist ein Fehler aufgetreten!
Die gewünschte Seite existiert nicht oder es ist ein interner Fehler aufgetreten!
Wenn Sie der Meinung sind, dass hier eine Fehlfunktion aufgetreten ist, so setzten Sie sich bitte mit uns in Verbindung und teilen uns folgende Angaben mit:
Event Name: onRequest
Exception type: expression
QueryString: lg=de&content=produkte&pg=anwendungen/baumesstechnik/neigungsmesser/bk-g-einfuehrbarer-neigungsmesser-5-und-10
E-Mail senden
Vielen Dank