Piezoelektrische Mikrofone / Dynamische Druckaufnehmer


Piezo-Electric-Microphones M/01
Piezo-Electric-Microphones M/01
Piezo-Electric-Microphones M/02
Piezo-Electric-Microphones M/02

Piezo-electric Microphones / Pressure Transducers

  • Mono-Axial
  • Charge Output
  • Vibration Compensated (/*A)
  • Case Isolated (/*I)

High sensitivity dynamic pressure transducers, finding application for high intensity acoustic, turbulence and cavitation measurements, particularly where these phenomena may be superimposed upon high static pressure fluid media. The sensing element converts axial pressure applied via a diaphragm to electrical charge.

Response to static loading comprises generation of an initial condition charge followed by exponentiation to zero at a rate determined by instrumentation properties and leakage, thus a pressure field comprising both static and dynamic components will convert to dynamic charge only, with the static element transparent. The charge sensitivity is the slope of the charge vs. pressure characteristic of the transducer, (ðq/ðp)/P up to its safe static pressure limit and will be invariant for Q vs. P linear.

Acoustic Properties

These relate to transducer dimensions and are application specific, being dependant upon level of obtrusiveness as seen by the fluid medium. Thus transducers ported through walls with diaphragms flush and therefore unobtrusive, have a worst case upper frequency limit determined by diaphragm diameter ≡ 0.5x acoustic wave length, i.e. 6kHz in air.

Microphones inserted into a fluid medium constitute an obstacle that will introduce boundary effects such as diffraction and reflection, of increasing significance at higher frequencies, and in the case of fluid flow, turbulence.

Vibration

This if present, represents a spurious signal source, generating an inertial charge by virtue of the inherent mass of the pressure sensing element. Its significance, determined by comparative acoustic and vibration frequency spectra and signal levels, possibly imposing a constraint on dynamic range. This may be raised by inclusion of a compensatory vibration sensor within the pressure transducer.

Application Notes

Sound pressure reference level : (0dB) = 2 x 10-4 µbar, i.e. 1bar = 194dB spl. The nominal 20nC/bar pressure sensitivity, together with an instrumentation noise level of 0.01pC, would presuppose a spl threshold of 68dB ex additional environmental noise sources. Axial vibration (worst case) in the case of uncompensated transducers (/F, /T) generates 148dB spl/g, reducing to 128dB spl/g in the case of the /FA & /TA accelerometer compensated devices.

Thus, in the latter case, 1mg axial acceleration would equal the hypothetical 68dB spl noise floor. Potential usage overlaps the domains of acoustic and explosive type phenomena, and is determined by noise and signal levels, the latter based on the charge handling capability of the associated instrumentation and perceived disadvantage of thermal charge generation.

Calibration

Pressure sensitivity is derived from axial vibration of the transducer with and without a mass attached to the diaphragm. This gives the charge sensitivity at ambient pressure (∂q/∂p)/Pamb. High ambient pressure operation should be preceded by proof pressure sensitivity stabilisation and hermeticity testing. Similarly elevated temperature operation will require a programme of thermal cycling.

Options

  • Charge vs. pressure up to 500 bar
  • Wideband temperature calibration -50/+300°C
  • Proof pressure test of transducers, transducers/cables to 150bar
  • Hermetic connectors
  • Integral cables
  • Case isolated signal for cmr

Model M/02:

Half size version of the M/01, doubling acoustic bandwidth, but at expense of 14dB reduction in sensitivity, thus 0.01pC noise equivalent acoustic signal threshold increases to 82dB (2.5mbar) M/02 application areas include air blast measurement, combustion gas acoustic measurement, fluid flow dynamics. Signals may be superimposed upon high static pressure backgrounds. Transducers are calibrated at ambient pressure.

Environmental

Both M/02s and M/01s have a variety of signal outlet options to cater for more extreme operating conditions. These encompass fluid immersion of transducer and cable, environments hazardous to cabling where cable armouring may be necessary and electrical interference.
 

TYPE

PRESSURE
SENSITIVITY
[nC/bar]

VIBRATION
SENSITIBITY
[pC/g]

FREQUENCY
[kHz]

TEMPERATURE
[°C]

CAPACITANCE

WEIGHT
[Gramme]

M/02/F 4/6 23 max 90 -50/+250 1.4/1.9 nF 46
M/02/FA 4/6 2.5 max 70 -50/+250 2.8/5.0 nF 56.5
M/02/T 4/6 23 max 90 -50/+250 1.4/1.9 nF 70
M/02/TA 4/6 2.5 max 70 -50/+250 2.8/5.0 nF 77
M/02/TI-1 1.5 10 60 -50/+500 800 pF (ex cable)  
M/01/F 18/22 80/130 40 +15/+250 3.6/4.2 nF 190
M/01/FA 18/22 10/15 30 +15/+250 5/6 nF 240
M/01/T 18/22 80/130 40 +15/+250 3.6/4.2 nF 240
M/01/TA 18/22 10/15 30 +15/+250 5/6 nF 320

 



E-Mail Passwort Login erfolgt über eine gesicherte SSL Verbindung jetzt registrieren!
ZSE Electronic GmbH

ZSE Produkt-Navigation

unser Aufnehmerprogramm
DMS-Qickfinder - finden Sie den richtigen DMS für Ihre Anwendung

Wir stellen aus:

SENSOR+TEST 2019 SENSOR+TEST 2019
Nürnberg, 25.6.-27.6.19
Stand Nr. 1-307
Jetzt gratis Eintritt sichern
Entry for free


german english