You are here
> Home
> Measurement Data Acquisition
> NTB - CAN-Network Terminal Box
NTB - CAN-Network Terminal Box
NTB Serie - CAN-Bus Strain Gauge Converter
NTB-100A-120 CAN-Bus Strain gauge converter
NTB-111A-350 CAN-Bus Strain gauge converter
Can-Bus converter for strain gages.
The NTB-Series provide signal conditioning and A/D-converters for four strain gauges, voltages or thermocouples per network terminal box. Up to 99 NTBs can be used in one distributed CAN-network for up to 396 channels.
Features:
- Easy CAN-Bus wiring for distributed data acquisition
- Maximum length of one CAN-Bus segment: 1km
- Four channels per NTB Box
- Direct connection of quarter bridges (120 or 350 ohms gage resistance)
- Direct connection of full- and half-bridges (120 to 1000 ohms gage resistance)
- One AC-power supply can drive up to eight NTBs
- Scaninterval: 0.5 Sec. and 1 Sec.
- Measurement range - strain: 0 ... ±300000 µm/m / -30 ... 70 °C (T-Series Civil-Engineering Transducers) Resolution: 1µm/m or 0,1°C
- Measurement range - voltage: ±10V / ±50V Resolution: 100µV / 1mV
- Measurement range - thermocouple: -200°C to +1300°C (depending on TC Type) Resolution: 0,1°C
- Accuracy (Strain): ±0,05%
- TEDS-Sensor ID Support
- Environmental: -10 ... 50 °C / 20 ... 85% RH (non condens.)
- DC-Power Input. 11 ... 16 VDC
- “Easy-to-use” Software (NTB-10A), SDK (DLLs) and MS-Excel macros
- Compatible to KYOWA Dataloggers and Recorders (SME and EDX Series)