DTP-E-S Drip-proof Large-Capacity Displacement Transducer (500 to 2000 mm)
| Performance | |
| Non-linearity [%RO] | +/-1 |
| Hysteresis [%RO] | +/-1 |
| Repeatability [%RO] | 0.1 max. |
| Rated output | 5 mV/V (10000x10–6 strain) |
| Cylic service life [times] | 10000 |
| Environmental Capability | |
| Operating temperature range [°C] | -10 – 55 |
| Electrical Characteristics | |
| Detection method | Potentiometer based |
| Safe excitation voitage [V] | 10 AC or DC |
| Recommened excitation voltage [V] | 1 – 5 AC or DC |
| Input resistance | 350 Ohm +/-5% |
| Output resistance | 350 Ohm +/-5% |
| Cable | 4-conductor (0.5 mm²) shielded chloroprene-coated cable of 10 mm diameter by 3 m long; bared at the tip |
| Mechanical Properties | |
| Safe overload rating [%] | 120 |
| Degree of protection |
IP67 (dripproof in conformity to JIS C 0920) |
| Enclolsure | Stainless steel finish |