You are here
> Home
> Transducer & Sen...
> Displacement
> DLT-AS/BS Induct...
> DLT-BS - Waterpr...
DLT-BS - Waterproof
| Performance | |
| Non-linearity [%RO] | +/-0.5 |
| Hysteresis [%RO] | +/-0.5 |
| Rated output | +/-2 mV/V (4000x10–6 strain) approx. |
| Environmental Capability | |
| Safe temperature range [°C] | -15 – 75 (no dew condensation) |
| Compensated temperature range [°C] | -10 – 60 (no dew condensation) |
| Temperature effect on zero balance [%RO/°C] | +/-0.01 |
| Temperature effect on output [%RO] | +/-0.01 |
| Electrical Characteristics | |
| Detection method | Inductance based |
| Safe excitation voitage [V] | 5 AC (carrier 5 kHz) |
| Recommened excitation voltage [V] | 2 AC or DC (carrier 5kHz) |
| Input resistance | 120 Ohm +/-1% |
| Output resistance | 120 Ohm +/-1% |
| Cable | 4-conductor (0.3 mm²) chloroprene-coated cable of 7.6 m diameter by 5 m long; terminated with an NDIS connector plug |