You are here  >  Home  >  Transducer & Sen...  >  Displacement  >  DLT-AS/BS Induct...  >  DLT-BS - Waterpr...

DLT-BS - Waterproof

Performance
Non-linearity [%RO] +/-0.5
Hysteresis [%RO] +/-0.5
Rated output +/-2 mV/V (4000x10–6 strain) approx.
 
Environmental Capability
Safe temperature range [°C] -15 – 75 (no dew condensation)
Compensated temperature range [°C] -10 – 60 (no dew condensation)
Temperature effect on zero balance [%RO/°C] +/-0.01
Temperature effect on output [%RO] +/-0.01
 
Electrical Characteristics
Detection method Inductance based
Safe excitation voitage [V] 5 AC (carrier 5 kHz)
Recommened excitation voltage [V] 2 AC or DC (carrier 5kHz)
Input resistance 120 Ohm +/-1%
Output resistance 120 Ohm +/-1%
Cable 4-conductor (0.3 mm²) chloroprene-coated cable of 7.6 m diameter by 5 m long; terminated with an NDIS connector plug