DTH-A Displacement Transducers
(5 to 100 mm)
| Performance | |
| Non-linearity [%RO] | +/-0.1 |
| Hysteresis [%RO] | 0.1 |
| Repeatability [%RO] | 0.1 max. |
| Rated output | 5 mV/V (10000 x10–6 strain) +/-0.1% |
| Environmental Capability | |
| Safe temperature range [°C] | -10 – 70 (no dew condensation) |
| Compensated temperature range [°C] | 0 – 60 (no dew condensation) |
| Temperature effect on zero balance [%RO/°C] | +/-0.01 |
| Temperature effect on output [%RO] | +/-0.01 |
| Safe excitation voitage [V] | 6 AC or DC |
| Input resistance | 350 Ohm +/-1% |
| Output resistance | 350 Ohm +/-1% |
| Cable | 4-conductor (0.065 mm²) vinyl-coated cable of 4 mm diameter by 2 m long; terminated with an NDIS connector plug |
| Frequency response | DC to approx. 2 Hz |
| Standard Accessories | |
| Fixing Band |
1 piece for DTH-A-5 to DTH-A-30, 2 pieces for DTH-A-50 and DTH-A-100 |
| Options | |
| Extension Rod | EB (dedicated to the DTH-A series) |
| Replacement Probes | X, XS, SH |
| Magnet Base | MB-B |