You are here  >  Home  >  Transducer & Sen...  >  Pressure  >  Differtial Press...  >  PDU-A Stainless ...

PDU-A Stainless Steel Differential Pressure Transducers (50 kPa to 2 MPa)

Performance
Repeatability [%RO] 0,1 or below
Rated output 1,5 mV/V (3000x10-6 strain) +/-0,5%
Response frequency range DC to 30 Hz
 
Environmental characteristics
Safe temperature/humidity range [°C] -30 – 90
Compensated temperature range [°C] -20 – 80
 
Electric characteristics
Safe excitation voitage [V] 15 AC or DC
Recommended excitation voltage [V] 1 – 10 AC or DC
Input resistance 350 Ohm +/-1 %
Output resistance 350 Ohm +/-1 %
Cable 0,3 mm², 4-conductor shielded chloroprene 5 m, Ø 7,6 mm, terminated in connector plug (NDIS)
 
Mechanical characteristics
Safe overload rating [%] 150 (even if 29,4 MPa overload should take place on either high or low side, the transducer will not be damaged)
Max. line pressure [MPa] 29,4 (300kgf/cm²)
Weight [kg] 6,4 (approx.)